S.M.A.R.T. Error MacOS 11 Big Sur Beta Installer
Solution 1:
I would load the app DriveDX which specifically looks for the SMART status of the drives. The app is not free but has a free trial period. You can use that to check your drive. It will tell you the SMART status and details about the drive. It very simple to use. Just start the app and it will start scanning your drives. Give it a minute or so to complete and display the results. See the image below for an example of the output. Yes my drives are failing or have failed.
Solution 2:
I would install Homebrew (brew.sh) if you don't have it already.
Then install smartmontools which provides a heck of a lot more data. This will provide far more detailed insight into the health of your disk. Read about it https://www.smartmontools.org
brew install smartmontools
smartctl -a disk0
You can diskutil -list
to get the drive id.
smartctl 7.1 2019-12-30 r5022 [Darwin 17.7.0 x86_64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SandForce Driven SSDs
Device Model: OWC Mercury Extreme Pro SSD
Serial Number: MXE12010E48B0468
LU WWN Device Id: 5 000000 000000468
Firmware Version: 361A13F0
User Capacity: 120,034,123,776 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Sat Jul 25 18:48:16 2020 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x7f) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Abort Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 5) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 116 110 050 Pre-fail Always - 0/145147714
5 Retired_Block_Count 0x0033 100 100 003 Pre-fail Always - 0
9 Power_On_Hours_and_Msec 0x0032 100 100 000 Old_age Always - 39376h+03m+21.330s
12 Power_Cycle_Count 0x0032 054 054 000 Old_age Always - 47865
171 Program_Fail_Count 0x0032 000 000 000 Old_age Always - 0
172 Erase_Fail_Count 0x0032 000 000 000 Old_age Always - 0
174 Unexpect_Power_Loss_Ct 0x0030 000 000 000 Old_age Offline - 6340
177 Wear_Range_Delta 0x0000 000 000 000 Old_age Offline - 2
181 Program_Fail_Count 0x0032 000 000 000 Old_age Always - 0
182 Erase_Fail_Count 0x0032 000 000 000 Old_age Always - 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
194 Temperature_Celsius 0x0022 030 030 000 Old_age Always - 30 (Min/Max 30/30)
195 ECC_Uncorr_Error_Count 0x001c 116 110 000 Old_age Offline - 0/145147714
196 Reallocated_Event_Count 0x0033 100 100 000 Pre-fail Always - 0
231 SSD_Life_Left 0x0013 099 099 010 Pre-fail Always - 0
233 SandForce_Internal 0x0000 000 000 000 Old_age Offline - 18752
234 SandForce_Internal 0x0032 000 000 000 Old_age Always - 20032
241 Lifetime_Writes_GiB 0x0032 000 000 000 Old_age Always - 20032
242 Lifetime_Reads_GiB 0x0032 000 000 000 Old_age Always - 35008
SMART Error Log not supported
SMART Self-test Log not supported
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.