error on \Device\Harddisk11\DR26 but Disk 11 doesn't exist
On a Windows 2008R2 server, I am getting this message in Event Viewer:
Log Name: System
Source: Disk
Date: 7/3/2013 4:25:54 AM
Event ID: 51
Task Category: None
Level: Warning
Keywords: Classic
User: N/A
Description:
An error was detected on device \Device\Harddisk11\DR26 during a paging operation.
Event Xml:
<Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
<System>
<Provider Name="Disk" />
<EventID Qualifiers="32772">51</EventID>
<Level>3</Level>
<Task>0</Task>
<Keywords>0x80000000000000</Keywords>
<TimeCreated SystemTime="2013-07-03T08:25:54.828401000Z" />
<EventRecordID>115066</EventRecordID>
<Channel>System</Channel>
<Security />
</System>
<EventData>
<Data>\Device\Harddisk11\DR26</Data>
<Binary>030080000100000000000000330004802D0100000E0000C000000000000000000000000000000000BE009A0500000000FFFFFFFF010000005800000802000008FD200A1242032040000200003C0000001080838780FAFFFF483DF28780FAFFFF0000000000000000D0285A0281FAFFFF0000000000000000008841060000000028000641880000000100000000000000000000000000000000000000000000000000000000000000</Binary>
</EventData>
</Event>
However, there is no disk 11 on this server. The disks stop at 10.
This particular server is a Hyper-V host in a cluster. All of the disks are either CSV disks or pass-through disks, all backed by iSCSI.
How can I identify which drive this is?
wmic
does not list the drive:
Caption DeviceID Model Partitions Size
LEFTHAND iSCSIDisk Multi-Path Disk Device \\.\PHYSICALDRIVE5 LEFTHAND iSCSIDisk Multi-Path Disk Device 1 2418923243520
LEFTHAND iSCSIDisk Multi-Path Disk Device \\.\PHYSICALDRIVE9 LEFTHAND iSCSIDisk Multi-Path Disk Device 1 1069286400
LEFTHAND iSCSIDisk Multi-Path Disk Device \\.\PHYSICALDRIVE10 LEFTHAND iSCSIDisk Multi-Path Disk Device 1 1759214661120
LEFTHAND iSCSIDisk Multi-Path Disk Device \\.\PHYSICALDRIVE4 LEFTHAND iSCSIDisk Multi-Path Disk Device 1 1979117521920
LEFTHAND iSCSIDisk Multi-Path Disk Device \\.\PHYSICALDRIVE7 LEFTHAND iSCSIDisk Multi-Path Disk Device 1 80525491200
LEFTHAND iSCSIDisk Multi-Path Disk Device \\.\PHYSICALDRIVE8 LEFTHAND iSCSIDisk Multi-Path Disk Device 1 536864025600
LEFTHAND iSCSIDisk Multi-Path Disk Device \\.\PHYSICALDRIVE2 LEFTHAND iSCSIDisk Multi-Path Disk Device 1 536864025600
LEFTHAND iSCSIDisk Multi-Path Disk Device \\.\PHYSICALDRIVE3 LEFTHAND iSCSIDisk Multi-Path Disk Device 1 536864025600
LEFTHAND iSCSIDisk Multi-Path Disk Device \\.\PHYSICALDRIVE1 LEFTHAND iSCSIDisk Multi-Path Disk Device 1 322118415360
LEFTHAND iSCSIDisk Multi-Path Disk Device \\.\PHYSICALDRIVE6 LEFTHAND iSCSIDisk Multi-Path Disk Device 0 1069286400
HP LOGICAL VOLUME SCSI Disk Device \\.\PHYSICALDRIVE0 HP LOGICAL VOLUME SCSI Disk Device 2 220122071040
This is a bit of a WAG but have you tried recompiling the iSCSI MOF files? I've come across similar behavior where NetApp's SnapDrive can't enumerate all the of the iSCSI drives on a particular server. This blog pointed me at this KB2001997.
Try comparing the results of the following WMI query on this server to another known good one:
Get-WmiObject -NameSpace Root\WMI MSiSCSIInitiator_PersistentDevices