Install the srvadmin-all package and dependencies following these instructions: http://linux.dell.com/repo/hardware/latest/

You may need to log out and in to set the $PATH correctly.

Then:

[root@poweredge ~]# omreport chassis pwrmonitoring
Power Consumption Information

Power Consumption
Index             : 2
Status            : Ok
Probe Name        : System Board Pwr Consumption
Reading           : 126 W
Warning Threshold : 896 W
Failure Threshold : 980 W

Amperage
PS1 Current 1 : 0.6 A
PS2 Current 2 : 0.2 A

Power Headroom
System Instantaneous Headroom : 766 W
System Peak Headroom          : 549 W

Power Tracking Statistics
Statistic               : Energy Consumption
Measurement Start Time  : Wed Oct 17 20:18:51 2012
Measurement Finish Time : Fri Nov 13 09:51:52 2015
Reading                 : 3041.1 kWh

Statistic              : System Peak Power
Measurement Start Time : Wed Oct 17 20:18:51 2012
Peak Time              : Tue Jun  2 10:42:27 2015
Peak Reading           : 351 W

Statistic              : System Peak Amperage
Measurement Start Time : Wed Oct 17 20:18:51 2012
Peak Time              : Wed Aug  5 07:09:49 2015
Peak Reading           : 1024.2 A

Solution 2:

In my case omreport chassis pwrmonitoring was maybe not giving the result I wanted.

Tested in 2021 on Proxmox 7

Working way to get

racadm get system.Power.Realtime.Power
racadm get system.Power.Realtime.Power
56 W | 191 Btu/hr

More data

racadm get system.Power
#Avg.LastDay=58 W | 198 Btu/hr
#Avg.LastHour=58 W | 198 Btu/hr
#Avg.LastWeek=57 W | 195 Btu/hr
#EnergyConsumption=25.455 KWh | 86878 Btu
#EnergyConsumption.Clear=******** (Write-Only)
#EnergyConsumption.StarttimeStamp=Sat Jul 03 17:05:13 2021
HotSpare.Enable=Enabled
HotSpare.PrimaryPSU=PSU1
#Max.Amps=0.7 Amps
#Max.Amps.Timestamp=Sat Jul 17 23:40:46 2021
#Max.Headroom=731 W | 2495 Btu/hr
#Max.LastDay=99 W | 338 Btu/hr
#Max.LastDay.Timestamp=Thu Jul 22 23:35:53 2021
#Max.LastHour=86 W | 294 Btu/hr
#Max.LastHour.Timestamp=Fri Jul 23 19:20:05 2021
#Max.LastWeek=152 W | 519 Btu/hr
#Max.LastWeek.Timestamp=Sat Jul 17 23:41:23 2021
#Max.Power=169 W | 577 Btu/hr
#Max.Power.Timestamp=Mon Jul 19 05:02:47 2021
#Max.PowerClear=******** (Write-Only)
#Min.LastDay=54 W | 184 Btu/hr
#Min.LastDay.Timestamp=Thu Jul 22 20:24:57 2021
#Min.LastHour=54 W | 184 Btu/hr
#Min.LastHour.Timestamp=Fri Jul 23 19:00:05 2021
#Min.LastWeek=53 W | 181 Btu/hr
#Min.LastWeek.Timestamp=Fri Jul 16 19:57:31 2021
PFCEnable=Disabled
#Realtime.Amps=0.2 Amps
#Realtime.Headroom=837 W | 2857 Btu/hr
#Realtime.Power=63 W | 215 Btu/hr
#RedundancyCapabilities=Not Redundant,Input Power Redundant
RedundancyPolicy=Not Redundant

Deprecated way

racadm getconfig -g cfgServerPower
root@pve:~# racadm getconfig -g cfgServerPower
# cfgServerActualPowerConsumption=65 W | 222 Btu/hr
# cfgServerPeakPowerConsumption=169 W | 577 Btu/hr
# cfgServerPeakPowerConsumptionTimestamp=Mon Jul 19 05:02:47 2021
# cfgServerPowerConsumptionClear=******** (Write-Only)
# cfgServerPowerLastHourAvg=58 W | 198 Btu/hr
# cfgServerPowerLastDayAvg=58 W | 198 Btu/hr
# cfgServerPowerLastWeekAvg=57 W | 195 Btu/hr
# cfgServerPowerLastHourMinPower=54 W | 184 Btu/hr
# cfgServerPowerLastHourMinTime=Fri Jul 23 18:58:59 2021
# cfgServerPowerLastHourMaxPower=86 W | 294 Btu/hr
# cfgServerPowerLastHourMaxTime=Fri Jul 23 18:50:01 2021
# cfgServerPowerLastDayMinPower=54 W | 184 Btu/hr
# cfgServerPowerLastDayMinTime=Thu Jul 22 20:24:57 2021
# cfgServerPowerLastDayMaxPower=99 W | 338 Btu/hr
# cfgServerPowerLastDayMaxTime=Thu Jul 22 23:35:53 2021
# cfgServerPowerLastWeekMinPower=53 W | 181 Btu/hr
# cfgServerPowerLastWeekMinTime=Fri Jul 16 19:40:13 2021
# cfgServerPowerLastWeekMaxPower=152 W | 519 Btu/hr
# cfgServerPowerLastWeekMaxTime=Sat Jul 17 23:41:23 2021
# cfgServerPowerInstHeadroom=835 W | 2850 Btu/hr
# cfgServerPowerPeakHeadroom=731 W | 2495 Btu/hr
# cfgServerActualAmperageConsumption=0.2 Amps
# cfgServerPeakAmperage=0.7 Amps
# cfgServerPeakAmperageTimeStamp=Sat Jul 17 23:40:46 2021
# cfgServerCumulativePowerConsumption=25.443 KWh | 86837 Btu
# cfgServerCumulativePowerConsumptionTimeStamp=Sat Jul 03 17:05:13 2021
# cfgServerCumulativePowerClear=******** (Write-Only)


RAC1168: The RACADM "getconfig" command will be deprecated in a
future version of iDRAC firmware. Run the RACADM 
"racadm get" command to retrieve the iDRAC configuration parameters.
For more information on the get command, run the RACADM command