Shocking? - MacBook stubby earthed charger UK
Solution 1:
This is so commonly misunderstood that I shall attempt to provide a short précis, then link to a good explanation which is not overly-technical.
Common misconception - earthing/grounding
Most small household appliances are not, in fact, earthed at all - even if there is a valid earth pin on the mains plug.
They are what is known as 'double insulated' & carry this logo
The 'transformers' on this type of equipment are not the same as in high-power equipment & don't use a step-down coil transformer, linear supply. Instead they use a switch-mode supply.
All PSUs, whether linear or switch-mode leak a small amount of current due to capacitance. In double-insulated devices there is no true ground/earth so the design is optimised to try to prevent this leakage.
Unfortunately, switch-mode supplies run at very high frequencies, so the smaller capacitance in the smaller transformer ends up leaking just as much as the larger capacitance in a larger transformer running at 50 or at 60Hz for example.
The leakage current is usually less than 1mA and is often as low as 10uA, but even at such low current, it can still be present and still can cause problems.
So - the tingle or buzz that you feel is in fact you becoming the temporary ground/earth for this circuit.
It is usually safe, & any reputable manufacturer will ensure their PSUs are well within tolerance.
Cheap copies are cheap because they don't bother with most of the safety circuitry… you know, the stuff that makes the expensive one expensive in the first place ;-)
Have look at http://www.unitechelectronics.com/sparks.htm for a much more detailed explanation. Though it is aimed at hi-fi users & deals in 240v mains, the basic principles are identical.
Solution 2:
In countries where the plugs to the mains are not earthed (or grounded to power as we say across the pond) you can buy and use a US cable that carries a third conductor for grounding/earthing and get your electrician to fit sockets or equivalent wiring past the Apple kit.
I have also seen people ground their work surface like you do in a static safe work environment. If the Mac can ground itself through the table, you won't feel the leakage voltage / current since you are no longer the best path to ground.
This tingly feeling bugs me to no end, but Apple does make adapted and cables to have a ground so you might need to use them over the standard UK kit. I'm "lightly shocked" the genius there didn't suggest more options for you.