HP P410i Array Controller and lost logical Drive
Solution 1:
HP ProLiant Smart Array RAID technology stores the array information on the actual drives and not on the controller. Disk drive position within the cage is EXTREMELY important.
- Turn the server off.
- Remove the power cables from the system.
- Remove the drives and place them back in the original drive order. I don't know if disks were moved, but go back to the original setup.
- Do not insert the 6th drive that you added after the fact.
- Reinsert the power cables and power the machine on.
- Watch the POST and boot process. If prompted by the Array BIOS utility, ensure the arrays are enabled and not disabled (often need to press "F2").
- See if the system boots and both arrays show up.
Please report back with what happens.
May I ask what you were trying to do by inserting the new drive? Please provide more detail.