The recommended maximum number of disks in a RAID system varies a lot. It depends on a variety of things:

  • Disk technology SATA tolerates smaller arrays than SAS/FC does, but this is changing.
  • RAID Controller limits The RAID controller itself may have fundamental maximums. If it is SCSI based and each visible disk is a LUN, the 7/14 rule holds true. If it FibreChannel based, it can have up to 120 or more visible disks.
  • RAID Controller processor If you go with any kind of parity RAID, the CPU in the RAID card will be the limiter on how fast you can write data. There will be a fundamental maximum for the card. You'll see it when a drive fails in a RAID5/6 LUN, as the performance drop will affect all LUNs associated with the RAID card.
  • Bus bandwidth U320 SCSI has its own limits, as does FibreChannel. For SCSI keeping RAID members on different channels can enhance parallelism and improve performance, if the controller supports it.

For SATA-based RAID, you don't want to have more than about 6.5TB of raw disk if you're using RAID5. Go past than and RAID6 is a much better idea. This is due to the non-recoverable read error rate. If the size of the array is too large, the chances of a non-recoverable read error occurring during the array rebuild after a loss get higher and higher. If that happens, it's very bad. Having RAID6 greatly reduces this exposure. However, SATA drives have been improving in quality lately, so this may not hold true for much longer.

The number of spindles in an array doesn't really worry me over much, as it's pretty simple to get to 6.5TB with 500GB drives on U320. If doing that, it would be a good idea to put half of the drives on one channel and half on the other just to reduce I/O contention on the bus side. SATA-2 speeds are such that even just two disks transferring at max-rate can saturate a bus/channel.

SAS disks have a lower MTBF rate than SATA (again, this is beginning to change) so the rules are less firm there.

There are FC arrays that use SATA drives internally. The RAID controllers there are very sophisticated, which muddies the rules of thumb. For instance, the HP EVA line of arrays groups disks into 'disk groups' on which LUNs are laid out. The controllers purposefully place blocks for the LUNs in non-sequential locations, and perform load-leveling on the blocks behind the scenes to minimize hot-spotting. Which is a long way of saying that they do a lot of the heavy lifting for you with regards to multiple channel I/O, spindles involved in a LUN, and dealing with redundancy.

Summing up, failure rates for disks doesn't drive the rules for how many spindles are in a RAID group, performance does. For the most part.


If you are looking for performance, then it is important to understand the interconnect that you're using to attach the drives to the array. For SATA or IDE, you will be looking at 1 or 2 per channel, respecitvely (assuming that you are using a controller with independent channels). For SCSI, this depends heavily on the bus topology. Early SCSI had a device limit of 7 device IDs per chain (aka. per controller), one of which had to be the controller itself, so you would have 6 devices per SCSI chain. Newer SCSI technologies allow for nearly double that number, so you would be looking at 12+. The key here is that the combined throughput of all drives can't exceed the capacity of the interconnect, otherwise your drives will be "idling' when they are at peak performance.

Keep in mind that the drives are not the only weak link here; each interconnect without redundancy results in a single failure point. If you don't believe me, set up a RAID 5 array on a single-chain SCSI controller, then short the controller out. Can you still get to your data? Yeah, that's what I thought.

Today, things have changed a wee bit. The drives haven't advanced a lot in terms of performance, but the advancement seen is significant enough that performance tends not to be an issue unless you are working with "drive farms", in which case you're talking about an entirely different infrastructure and this answer/conversation is moot. What you will probably worry about more is data redundancy. RAID 5 was good in its heyday because of several factors, but those factors have changed. I think you'll find that RAID 10 might be more to your liking, as it will provide additional redundancy against drive failures while increasing read performance. Write performance will suffer slightly, but that can be mitigated through an increase in active channels. I would take a 4-drive RAID 10 setup over a 5-drive RAID 5 setup any day, because the RAID 10 setup can survive a (specific case of) two-drive failure, whereas the RAID 5 array would simply roll over and die with a two-drive failure. In addition to providing slightly better redundancy, you can also mitigate the "controller as a single point of failure" situation by splitting the mirror into two equal parts, with each controller handling just the stripe. In the event of a controller failure, your stripe will not be lost, only the mirror effect.

Of course, this may be completely wrong for your circumstances as well. You're going to need to look at the tradeoffs involved between speed, capacity, and redundancy. Like the old engineering joke, "better-cheaper-faster, pick any two", you'll find you can live with a configuration that suits you, even if it's not optimal.